[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15034056
Date Manufactured	04/01/2013
Lot	WO0000109256823
DesignStudio ID	19713
Target Plexity	63
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
ABL1	NM_007313	6607434	1	2	Homo sapiens	hg19	9	133729590	133730231	GGCCAGTGGAGATAACACTCTAAGCATA	1	AGGCTATAATCACAATGGGGAATGG	1	PLUS	ILLUMINA	1.856	false	FromReportXYZ;FromStudyXYZ
ANAPC2	NM_013366	6819402	12	11	Homo sapiens	hg19	9	140069696	140069603	CCAGGCCGACCAGAAGGAGGAGGA	2	TTCTGGACGTACATCCAGGCCAT	2	MINUS	ILLUMINA	1.243	false	FromStudyXYZ
ATM	NM_000051	6688745	0	1	Homo sapiens	hg19	11	108093881	108098356	GGTTGATACTACTTTGACCTTCCGAGTG	1	TGTGTGTTCTGAAATTGTGAACCATGAG	1	PLUS	ILLUMINA	1.935	false	
ATR	NM_001184	6798606	46	45	Homo sapiens	hg19	3	142171978	142168429	CACTGAATGAAACTGGAGAAGTTGTCA	1	CTTGACATTGAGCAGCGACTACAAG	1	MINUS	ILLUMINA	1.884	false	
BRCA1	NM_007300	6730125	14	13	Homo sapiens	hg19	17	41228510	41226537	TCTACCAGTAAAAATAAAGAACCAGGAGTG	1	TCATCCCCTTCTAAATGCCCATCATTAG	1	MINUS	ILLUMINA	1.738	false	
BRCA2	NM_000059	6803185	13	14	Homo sapiens	hg19	13	32929393	32930594	TAACTTTCACAAAGTGTGAAGAAGAACC	1	TTTAATTACAAGTCTTCAGAATGCCAGAG	1	PLUS	ILLUMINA	1.818	false	
CCNA2	NM_001237	6736142	2	1	Homo sapiens	hg19	4	122743566	122742245	GGTCCCTCTTGATTATCCAATGGATGG	1	GTCACCACATACTATGGACATGTCA	1	MINUS	ILLUMINA	1.878	false	
CCNB1	NM_031966	6796317	7	8	Homo sapiens	hg19	5	68473144	68473389	GTCATGGTAAATCAAGGACTTACAAAGC	1	AGTATGCCACATCGAAGCATGCTAAG	1	PLUS	ILLUMINA	1.934	false	
CCNB2	NM_004701	6606569	7	8	Homo sapiens	hg19	15	59415788	59417009	AATGTGGTGAAAGTAAATGAAAACTTAAC	2	CAAGCAGCAAACTCCTGAAGATCAG	2	PLUS	ILLUMINA	1.691	false	
CCND1	NM_053056	6833730	0	1	Homo sapiens	hg19	11	69456247	69457833	ATGCGGAAGATCGTCGCCACCTGGAT	1	AGAAGTGCGAGGAGGAGGTCTT	9	PLUS	ILLUMINA	1.328	false	
CCND2	NM_001759	6791918	3	4	Homo sapiens	hg19	12	4398124	4409055	GAGCTGCTGGCTAAGATCACCAACA	3	TCAAAGCTTGCCAGGAGCAGATT	9	PLUS	ILLUMINA	1.498	false	
CCND3	NM_001760	6852976	3	2	Homo sapiens	hg19	6	41904982	41904412	GCATGCCCAGACCTTTTTGGCCCTCT	2	CGCCATCCATGATCGCCACGGG	1	MINUS	ILLUMINA	1.258	false	
CCNE1	NM_001238	6797467	5	6	Homo sapiens	hg19	19	30308412	30311644	AAAAATGCGAGCAATTCTTCTGGATTGG	1	GTCTATAAACTTCACAGGGAGACCTTT	1	PLUS	ILLUMINA	1.961	false	
CCNG2	NM_004354	6716116	1	2	Homo sapiens	hg19	4	78079793	78080559	AGGGCTGAGTTTGATTGAGGCTA	4	TGTGTCCAGGATTGAGAAATGCCAAAG	2	PLUS	ILLUMINA	1.629	false	
CCNH	NM_001239	6658847	8	7	Homo sapiens	hg19	5	86690864	86690290	GATTACGTCTCAAAGAAATCCAAACATGAG	2	TGATGACGACCTGGTAGAATCTCTCT	3	MINUS	ILLUMINA	1.734	false	
CDC16	NM_003903	6760227	11	12	Homo sapiens	hg19	13	115016122	115022581	ACTTCACAGCAGCACAGCTGATGAAA	1	GTCATTTGCCTATGCTGTATATTGGAT	1	PLUS	ILLUMINA	1.943	false	
CDC20	NM_001255	6687539	7	8	Homo sapiens	hg19	1	43826608	43826832	CACCCAGCATCAAGGGGCTGTCAA	4	CCCTGGCAGTCCAATGTCCTGGCAACA	2	PLUS	ILLUMINA	1.549	false	
CDC25A	NM_001789	6812795	14	13	Homo sapiens	hg19	3	48200836	48200554	GGGATACAAGGAGTTCTTTATGAAATGCC	1	TACCGGCCCATGCACCACGAGGA	2	MINUS	ILLUMINA	1.412	false	
CDC25C	NM_001790	6647131	7	6	Homo sapiens	hg19	5	137654916	137627792	ATTAATGGAGTTTTCCCTGAAAGATCAAG	1	GCCTATATCGCTCCCCGTCGAT	2	MINUS	ILLUMINA	1.326	false	
CDC34	NM_004359	6694734	3	4	Homo sapiens	hg19	19	537119	541362	AAGGATCGGGAGTACACAGACATCAT	1	AAGCAGGTCCTGGGGACCAAGGT	6	PLUS	ILLUMINA	1.533	false	
CDC6	NM_001254	6831599	0	1	Homo sapiens	hg19	17	38444302	38445690	GCGGAGCTGGGTGAAGGCTGCGGGTT	1	CGTCATGCCTCAAACCCGATCC	2	PLUS	ILLUMINA	1.113	false	
CDK1	NM_001786	6732015	2	3	Homo sapiens	hg19	10	62544585	62545454	CTATTAAAGGAACTTCGTCATCCAAATAT	1	GATGTGCTTATGCAGGATTCCAGGTT	1	PLUS	ILLUMINA	1.803	false	
CDK2	NM_001798	6807934	2	3	Homo sapiens	hg19	12	56361923	56362604	TCTCACTGGCATTCCTCTTCCCCTCAT	1	CAGGGCCTAGCTTTCTGCCATT	19	PLUS	ILLUMINA	1.427	false	
CDK4	NM_000075	6769529	1	0	Homo sapiens	hg19	12	58145975	58145498	CCCGATAACGGGCCGCCCCCACAGCA	1	GGCTACCTCTCGATATGAGCCAG	2	MINUS	ILLUMINA	1.188	false	
CDK6	NM_001259	6649879	7	6	Homo sapiens	hg19	7	92247394	92244589	AACAGATATCGATGAACTAGGCAAAGACC	1	ATTTAACCCAGCCAAAAGAATATCTGCC	1	MINUS	ILLUMINA	1.861	false	
CDK7	NM_001799	6806863	1	2	Homo sapiens	hg19	5	68531253	68548271	CACCAACCAAATTGTCGCCATTAAGA	2	CAAACTTGGACATAGATCAGAAGCT	2	PLUS	ILLUMINA	1.853	false	
CDK8	NM_001260	6732509	0	1	Homo sapiens	hg19	13	26828874	26911747	TGGTCACGTCTACAAAGCCAAGAGGAA	2	CTATGCTTTAAAACAAATAGAAGGAACTG	1	PLUS	ILLUMINA	1.809	false	
CDKN1A	NM_078467	6677447	2	3	Homo sapiens	hg19	6	36652287	36653560	TCTCAGGGTCGAAAACGGCGGCAGA	1	TCCAAACGCCGGCTGATCTTCT	1	PLUS	ILLUMINA	1.238	false	
CDKN1B	NM_004064	6847969	1	2	Homo sapiens	hg19	12	12871854	12874013	CCTGGCCTCAGAAGACGTCAAACGTAAA	1	TCCTTGTTTATCAGATACATCACTGCTTG	1	PLUS	ILLUMINA	1.821	false	
CHEK1	NM_001114121	6747216	3	4	Homo sapiens	hg19	11	125499163	125499315	GATTCTTCCATCAACTCATGGCAGG	1	TTTATCTGCATGGTATTGGAATAACTCAC	1	PLUS	ILLUMINA	1.753	false	
CHEK2	NM_001005735	6675109	1	0	Homo sapiens	hg19	22	29137768	29130706	GCTGCGGAGAGTGTGCGGCTCCAGGT	1	TCTCGGGAGTCGGATGTTGAGG	5	MINUS	ILLUMINA	1.122	false	
CREB3	NM_006368	6701637	4	5	Homo sapiens	hg19	9	35735182	35735346	AGAAGGTGTATGTTGGGGGTTTAGAG	1	CCCAGAATATGGAGCTTCAGAACAAAG	1	PLUS	ILLUMINA	1.967	false	
CRY1	NM_004075	6848943	12	11	Homo sapiens	hg19	12	107386573	107385778	TTGGTCCTAAAGTCCAGAGACAGAGCA	1	AAACATTCAGGAGGAATACTGTTGCAG	1	MINUS	ILLUMINA	1.98	false	
CRY2	NM_021117	6682333	1	2	Homo sapiens	hg19	11	45877611	45880316	GCCAGCCGACGTGTTCCCAAGGCTGTT	1	GTGACCCGCTTGACCTTTGAATATGA	1	PLUS	ILLUMINA	1.734	false	
CUL1	NM_003592	6820534	2	3	Homo sapiens	hg19	7	148451206	148454108	GGAATTTTTGAAGAATTACTTGACAAATCT	2	AAGATTTGATGGATGAGAGTGTACTGA	2	PLUS	ILLUMINA	1.672	false	
E2F1	NM_005225	6647904	4	3	Homo sapiens	hg19	20	32266010	32265344	CTCTCCGAGGACACTGACAGCCA	5	TGGCCTACGTGACGTGTCAGGACCTT	1	MINUS	ILLUMINA	1.433	false	
E2F4	NM_001950	6601678	0	1	Homo sapiens	hg19	16	67226238	67226685	CAAGGACGGCGTGCTTGACCTCAA	3	GCAGCTGACACCCTAGCTGTAC	7	PLUS	ILLUMINA	1.161	false	
GADD45A	NM_001924	6771929	2	3	Homo sapiens	hg19	1	68152242	68153384	CCCCGGACCTGCACTGCGTGCTGGTGA	1	CAATGGAAGGATCCTGCCTTAAGTCA	1	PLUS	ILLUMINA	1.598	false	
MAD2L1	NM_002358	6734812	1	0	Homo sapiens	hg19	4	120987822	120986962	GCGGGAGCGCCGAAATCGTGGCCGAGTT	2	AACAGCATTTTATATCAGCGTGGCA	4	MINUS	ILLUMINA	1.524	false	
MAD2L2	NM_006341	6661217	2	1	Homo sapiens	hg19	1	11740625	11740517	CTCACACGACAAGACCTCAACTTTG	1	GTGCTCTGCGAGTTCCTGGAGGT	6	MINUS	ILLUMINA	1.455	false	
MCM2	NM_004526	6806177	7	8	Homo sapiens	hg19	3	127327832	127334733	CTAGCCTCTCCAAGGATCAGCAGAT	1	TCTTTGCCAGCATTGCTCCTTCCATCTA	1	PLUS	ILLUMINA	1.821	false	
MCM3	NM_002388	6650620	9	8	Homo sapiens	hg19	6	52141073	52138697	TGGCAGCTGCCAACCCTGTCTA	24	TCCAATGGAGAACATTGGGCTACAG	1	MINUS	ILLUMINA	1.341	false	
MCM4	NM_182746	6676265	2	3	Homo sapiens	hg19	8	48874208	48874643	TGTTTTCCAGCCCTCCCCAAATGCATT	1	TATCCCTCTTGACTTTGATGTTAGTTCACC	1	PLUS	ILLUMINA	1.738	false	
MCM5	NM_006739	6735582	0	1	Homo sapiens	hg19	22	35796173	35796466	CCTGGTTTGTGAAGTGCGGAAAA	3	TTCGACGATCCTGGCATTTTCTACAG	1	PLUS	ILLUMINA	1.603	false	
MDM2	NM_002392	6606061	0	1	Homo sapiens	hg19	12	69202239	69203026	CCAAGCGCGAAAACCCCGGATGGTGA	1	ATACCAACATGTCTGTACCTACTGATGG	1	PLUS	ILLUMINA	1.767	false	
MNAT1	NM_002431	6680158	6	7	Homo sapiens	hg19	14	61346526	61434975	CTGAGCTTGAGATGCTAGGAAGACTTG	2	AAACCATGTCAGAGCTGCCTCAC	8	PLUS	ILLUMINA	1.611	false	
MRE11A	NM_005591	6650560	19	18	Homo sapiens	hg19	11	94163081	94153346	ATCGAAAGGGGTTGATTTTGAATCAAG	2	ATGATGATGATGATCCTTTTATGAACAC	1	MINUS	ILLUMINA	1.902	false	
PER1	NM_002616	6744210	17	16	Homo sapiens	hg19	17	8049279	8048305	GTGGGAGACAAGAAGCCCCCGGAGT	1	TCATGATGGAGGACCTGCCTGG	10	MINUS	ILLUMINA	1.187	false	
PER2	NM_022817	6652659	9	8	Homo sapiens	hg19	2	239174161	239171698	ACACCAAATTGTTTGTTCCAGGATGTG	1	GCGGTCCCTCTCCTGGGCTACCTA	1	MINUS	ILLUMINA	1.623	false	
PER3	NM_016831	6817847	18	19	Homo sapiens	hg19	1	7895971	7897089	GAGCGCATTCTCATGACATACCAGGTA	1	GTTAAAGAAGTTGTACTAAAAGAAGACCTG	1	PLUS	ILLUMINA	1.728	false	
RAD51	NM_133487	6791116	4	5	Homo sapiens	hg19	15	41001284	41011034	GATCTGTCATACGCTAGCTGTCACCT	1	CCCATTGACCGGGGTGGAGGTGAAGGAAA	1	PLUS	ILLUMINA	1.697	false	
RB1	NM_000321	6839634	16	17	Homo sapiens	hg19	13	48955547	49027169	CATCGAATCATGGAATCCCTTGCATG	1	ATTTGATCTTATTAAACAATCAAAGGACCG	1	PLUS	ILLUMINA	1.691	false	
RBBP8	NM_203291	6639393	1	2	Homo sapiens	hg19	18	20516887	20526443	ACAAAACTAAAAGAATGTCATGATAGAGAA	1	AAAGTAACCAAGCTAAAACAGGAACGA	1	PLUS	ILLUMINA	1.677	false	
RBL1	NM_002895	6827736	1	0	Homo sapiens	hg19	20	35724184	35717520	TTTACTGCCATCCGAGGCAACTACA	1	AGTTACACACTGGTTGGCATGTTCA	1	MINUS	ILLUMINA	1.778	false	
RBL2	NM_005611	6620292	0	1	Homo sapiens	hg19	16	53468680	53472968	GCAGCATGAGCGAAAGCTACAC	8	ATTGGTTAGCATGTGCCTTATATGTGGC	1	PLUS	ILLUMINA	1.446	false	
SKP2	NM_032637	6813061	5	6	Homo sapiens	hg19	5	36170510	36171745	TTTGCCCTGCAGACTTTGCTAAGCA	1	AACCTCTCCTGGTGTTTTGATTTCACTG	1	PLUS	ILLUMINA	1.849	false	
SMAD4	NM_005359	6817287	0	1	Homo sapiens	hg19	18	48556961	48573333	GAGCGGACTCCCCTCGCCACCG	3	TGTCTAACAATTTTCCTTGCAACGTTAGC	1	PLUS	ILLUMINA	1.211	false	
TFDP1	NM_007111	6690973	9	10	Homo sapiens	hg19	13	114290973	114292176	GCCAGAAGTCTGGTCCCCAAGGCTCT	6	GAGGCGTGTTCATCACGACGGCA	7	PLUS	ILLUMINA	1.382	false	
TFDP2	NM_001178138	6747805	11	10	Homo sapiens	hg19	3	141682660	141678675	AACAGTCATAGATTGCAGCATCTCCAG	1	TATCTTTTCAATTTTGACAACACCTTTGAG	1	MINUS	ILLUMINA	1.723	false	
TGFB1	NM_000660	6836773	6	5	Homo sapiens	hg19	19	41838040	41837102	TACATTTGGAGCCTGGACACGCAGTA	1	ACAACCAGCATAACCCGGGCGC	1	MINUS	ILLUMINA	1.37	false	
TIMELESS	NM_003920	6708351	13	12	Homo sapiens	hg19	12	56822033	56818917	GAGCGATTCTGTCGGAGCCGTGGGAA	1	GGAAGAAGAAGAAGAAGGTCCTAGA	6	MINUS	ILLUMINA	1.692	false	
TP53	NM_001126114	6709182	7	6	Homo sapiens	hg19	17	7577500	7577151	ACCATCATCACACTGGAAGACTCCA	2	AATCTACTGGGACGGAACAGCTTTG	1	MINUS	ILLUMINA	1.771	false	
WEE1	NM_003390	6644367	1	2	Homo sapiens	hg19	11	9597604	9597814	GACAGTGTCGTCGTAGAAAGAGAACGTA	1	AAGACATGGAAGCCAGTGATTATGAGC	4	PLUS	ILLUMINA	1.962	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
ABL1	NM_007313	6607434	FIVE_PRIME	false	1	2	PLUS	CCATTCCCCATTGTGATTATAGCCTAAGACCCGGAGCTTTTCACCTTTAGTTATGCTTAGAGTGTTATCTCCACTGGCC
ANAPC2	NM_013366	6819402	THREE_PRIME	false	12	11	MINUS	ATGGCCTGGATGTACGTCCAGAAGAGCAGCAGCTCCTCCTCCTTCTGGTCGGCCTGG
ATM	NM_000051	6688745	FIVE_PRIME	false	0	1	PLUS	CTCATGGTTCACAATTTCAGAACACACATCACTGTCACTGCACTCGGAAGGTCAAAGTAGTATCAACC
ATR	NM_001184	6798606	THREE_PRIME	false	46	45	MINUS	CTTGTAGTCGCTGCTCAATGTCAAGAACATGGGTCTTGGCCTTTTCATTGACAACTTCTCCAGTTTCATTCAGTG
BRCA1	NM_007300	6730125	CENTER	false	14	13	MINUS	CTAATGATGGGCATTTAGAAGGGGATGACCTTTCCACTCCTGGTTCTTTATTTTTACTGGTAGA
BRCA2	NM_000059	6803185	CENTER	false	13	14	PLUS	CTCTGGCATTCTGAAGACTTGTAATTAAATCTAAAGGTTCTTCTTCACACTTTGTGAAAGTTA
CCNA2	NM_001237	6736142	FIVE_PRIME	false	2	1	MINUS	TGACATGTCCATAGTATGTGGTGACTCAAAACTACCATCCATTGGATAATCAAGAGGGACC
CCNB1	NM_031966	6796317	THREE_PRIME	false	7	8	PLUS	CTTAGCATGCTTCGATGTGGCATACTTGTTCTTGACAGTCATGTGCTTTGTAAGTCCTTGATTTACCATGAC
CCNB2	NM_004701	6606569	THREE_PRIME	false	7	8	PLUS	CTGATCTTCAGGAGTTTGCTGCTTGCATACTTATTCTTGATGGCGATGAATTTAGTTAAGTTTTCATTTACTTTCACCACATT
CCND1	NM_053056	6833730	FIVE_PRIME	false	0	1	PLUS	AAGACCTCCTCCTCGCACTTCTGTTCCTCGCAGACCTCCAGCATCCAGGTGGCGACGATCTTCCGCAT
CCND2	NM_001759	6791918	THREE_PRIME	false	3	4	PLUS	AATCTGCTCCTGGCAAGCTTTGAGACAATCCACGTCTGTGTTGGTGATCTTAGCCAGCAGCTC
CCND3	NM_001760	6852976	FIVE_PRIME	false	3	2	MINUS	CCCGTGGCGATCATGGATGGCGGGTACATGGCAAAGGTATAATCTGTAGCACAGAGGGCCAAAAAGGTCTGGGCATGC
CCNE1	NM_001238	6797467	CENTER	false	5	6	PLUS	AAAGGTCTCCCTGTGAAGTTTATAGACTTCACACACCTCCATTAACCAATCCAGAAGAATTGCTCGCATTTTT
CCNG2	NM_004354	6716116	FIVE_PRIME	false	1	2	PLUS	CTTTGGCATTTCTCAATCCTGGACACAAAGTGTTATCATTCTCCGGGGTAGCCTCAATCAAACTCAGCCCT
CCNH	NM_001239	6658847	THREE_PRIME	false	8	7	MINUS	AGAGAGATTCTACCAGGTCGTCATCAGTCCATTCTTCCTCCTCATGTTTGGATTTCTTTGAGACGTAATC
CDC16	NM_003903	6760227	CENTER	false	11	12	PLUS	ATCCAATATACAGCATAGGCAAATGACACCCTTTCATCAGCTGTGCTGCTGTGAAGT
CDC20	NM_001255	6687539	CENTER	false	7	8	PLUS	TGTTGCCAGGACATTGGACTGCCAGGGACACCATGCTACGGCCTTGACAGCCCCTTGATGCTGGGTG
CDC25A	NM_001789	6812795	THREE_PRIME	false	14	13	MINUS	TCCTCGTGGTGCATGGGCCGGTAGCTAGGGGGCTCACAGTAAGACTGGCATTTCATAAAGAACTCCTTGTATCCC
CDC25C	NM_001790	6647131	CENTER	false	7	6	MINUS	ATCGACGGGGAGCGATATAGGCCACTTCTGCTCACCTTTGCTTCTTGATCTTTCAGGGAAAACTCCATTAAT
CDC34	NM_004359	6694734	THREE_PRIME	false	3	4	PLUS	ACCTTGGTCCCCAGGACCTGCTTCCGGATGATGTCTGTGTACTCCCGATCCTT
CDC6	NM_001254	6831599	FIVE_PRIME	false	0	1	PLUS	GGATCGGGTTTGAGGCATGACGACAGCACAGCTCAGGCCTCGCCGGAACCCGCAGCCTTCACCCAGCTCCGC
CDK1	NM_001786	6732015	FIVE_PRIME	false	2	3	PLUS	AACCTGGAATCCTGCATAAGCACATCCTGAAGACTGACTATATTTGGATGACGAAGTTCCTTTAATAG
CDK2	NM_001798	6807934	CENTER	false	2	3	PLUS	AATGGCAGAAAGCTAGGCCCTGGAGCAGCTGGAACAGATAGCTCTTGATGAGGGGAAGAGGAATGCCAGTGAGA
CDK4	NM_000075	6769529	FIVE_PRIME	false	1	0	MINUS	CTGGCTCATATCGAGAGGTAGCCATTCTCAGATCAAGGGAGACCCTCACGCCAGCCCGGGGTGCTGTGGGGGCGGCCCGTTATCGGG
CDK6	NM_001259	6649879	THREE_PRIME	false	7	6	MINUS	GGCAGATATTCTTTTGGCTGGGTTAAATGTCAAACACTTCAGAAGTAGGTCTTTGCCTAGTTCATCGATATCTGTT
CDK7	NM_001799	6806863	FIVE_PRIME	false	1	2	PLUS	AGCTTCTGATCTATGTCCAAGTTTGATTTTCTTAATGGCGACAATTTGGTTGGTG
CDK8	NM_001260	6732509	FIVE_PRIME	false	0	1	PLUS	CAGTTCCTTCTATTTGTTTTAAAGCATAGTCTTTATCATCCTTCCCATCTTTCCTCTTGGCTTTGTAGACGTGACCA
CDKN1A	NM_078467	6677447	FIVE_PRIME	false	2	3	PLUS	AGAAGATCAGCCGGCGTTTGGAGTGGTAGAAATCTGTCATGCTGGTCTGCCGCCGTTTTCGACCCTGAGA
CDKN1B	NM_004064	6847969	THREE_PRIME	false	1	2	PLUS	CAAGCAGTGATGTATCTGATAAACAAGGAAACATATTCTTAATTCGAGCTGTTTACGTTTGACGTCTTCTGAGGCCAGG
CHEK1	NM_001114121	6747216	FIVE_PRIME	false	3	4	PLUS	GTGAGTTATTCCAATACCATGCAGATAAACCACCCCTGCCATGAGTTGATGGAAGAATC
CHEK2	NM_001005735	6675109	FIVE_PRIME	false	1	0	MINUS	CCTCAACATCCGACTCCCGAGACATCACGACCGCGTGAGCCCACCTGGAGCCGCACACTCTCCGCAGC
CREB3	NM_006368	6701637	CENTER	false	4	5	PLUS	CTTTGTTCTGAAGCTCCATATTCTGGGCTGTGTATTTCAAGACCCTGCTCTCTAAACCCCCAACATACACCTTCT
CRY1	NM_004075	6848943	THREE_PRIME	false	12	11	MINUS	CTGCAACAGTATTCCTCCTGAATGTTTTCTAATTAGTGCTCTGTCTCTGGACTTTAGGACCAA
CRY2	NM_021117	6682333	FIVE_PRIME	false	1	2	PLUS	TCATATTCAAAGGTCAAGCGGGTCACTCCCCATTCCTTGAACAGCCTTGGGAACACGTCGGCTGGC
CUL1	NM_003592	6820534	CENTER	false	2	3	PLUS	TCAGTACACTCTCATCCATCAAATCTTCTCCATCCTTAAGAAGATTTGTCAAGTAATTCTTCAAAAATTCC
E2F1	NM_005225	6647904	CENTER	false	4	3	MINUS	AAGGTCCTGACACGTCACGTAGGCCAGGCGCTGGCTGTCAGTGTCCTCGGAGAG
E2F4	NM_001950	6601678	FIVE_PRIME	false	0	1	PLUS	GTACAGCTAGGGTGTCAGCTGCCAGCTTGAGGTCAAGCACGCCGTCCTTG
GADD45A	NM_001924	6771929	FIVE_PRIME	false	2	3	PLUS	TGACTTAAGGCAGGATCCTTCCATTGAGATGAATGTGGATTCGTCACCAGCACGCAGTGCAGGTCCGGGG
MAD2L1	NM_002358	6734812	FIVE_PRIME	false	1	0	MINUS	TGCCACGCTGATATAAAATGCTGTTGATGCCGAATGAGAAGAACTCGGCCACGATTTCGGCGCTCCCGC
MAD2L2	NM_006341	6661217	FIVE_PRIME	false	2	1	MINUS	ACCTCCAGGAACTCGCAGAGCACATCGGCCACCACTTGGCCAAAGTTGAGGTCTTGTCGTGTGAG
MCM2	NM_004526	6806177	CENTER	false	7	8	PLUS	TAGATGGAAGGAGCAATGCTGGCAAAGATCTTCTCTCCGATCTGCTGATCCTTGGAGAGGCTAG
MCM3	NM_002388	6650620	CENTER	false	9	8	MINUS	CTGTAGCCCAATGTTCTCCATTGGAGTCTTATACTGGTCATACCTGCCGTAGACAGGGTTGGCAGCTGCCA
MCM4	NM_182746	6676265	FIVE_PRIME	false	2	3	PLUS	GGTGAACTAACATCAAAGTCAAGAGGGATAGCTGAAGAATGCATTTGGGGAGGGCTGGAAAACA
MCM5	NM_006739	6735582	FIVE_PRIME	false	0	1	PLUS	CTGTAGAAAATGCCAGGATCGTCGAATCCCGACATGACTGCGCCTCTGGTTTTCCGCACTTCACAAACCAGG
MDM2	NM_002392	6606061	FIVE_PRIME	false	0	1	PLUS	CCATCAGTAGGTACAGACATGTTGGTATTGCACATTTGCCTGCTCCTCACCATCCGGGGTTTTCGCGCTTGG
MNAT1	NM_002431	6680158	THREE_PRIME	false	6	7	PLUS	GTGAGGCAGCTCTGACATGGTTTAAATACCCAAGTCTTCCTAGCATCTCAAGCTCAG
MRE11A	NM_005591	6650560	THREE_PRIME	false	19	18	MINUS	GTGTTCATAAAAGGATCATCATCATCATCCTCACTTGATTCAAAATCAACCCCTTTCGAT
PER1	NM_002616	6744210	CENTER	false	17	16	MINUS	CCAGGCAGGTCCTCCATCATGATGATGTCCGACTCCGGGGGCTTCTTGTCTCCCAC
PER2	NM_022817	6652659	CENTER	false	9	8	MINUS	TAGGTAGCCCAGGAGAGGGACCGCCCTTTCATCCACATCCTGGAACAAACAATTTGGTGT
PER3	NM_016831	6817847	THREE_PRIME	false	18	19	PLUS	CAGGTCTTCTTTTAGTACAACTTCTTTAACCCTCTCAGGTACCTGGTATGTCATGAGAATGCGCTC
RAD51	NM_133487	6791116	CENTER	false	4	5	PLUS	TTTCCTTCACCTCCACCCCGGTCAATGGGAAGCTGGCAGGTGACAGCTAGCGTATGACAGATC
RB1	NM_000321	6839634	CENTER	false	16	17	PLUS	CGGTCCTTTGATTGTTTAATAAGATCAAATAAAGGTGAATCTGAGAGCCATGCAAGGGATTCCATGATTCGATG
RBBP8	NM_203291	6639393	FIVE_PRIME	false	1	2	PLUS	TCGTTCCTGTTTTAGCTTGGTTACTTTTACTTGTAAACCTTGTACTTCTCTATCATGACATTCTTTTAGTTTTGT
RBL1	NM_002895	6827736	FIVE_PRIME	false	1	0	MINUS	TGAACATGCCAACCAGTGTGTAACTTCTCCCTCTAGGCTGTAGTTGCCTCGGATGGCAGTAAA
RBL2	NM_005611	6620292	FIVE_PRIME	false	0	1	PLUS	GCCACATATAAGGCACATGCTAACCAATGAAGATCATTTCCCTCCAGCGTGTAGCTTTCGCTCATGCTGC
SKP2	NM_032637	6813061	CENTER	false	5	6	PLUS	CAGTGAAATCAAAACACCAGGAGAGGTTCAGCTCATCCAGTCTGGAACAGCTGCTTAGCAAAGTCTGCAGGGCAAA
SMAD4	NM_005359	6817287	FIVE_PRIME	false	0	1	PLUS	GCTAACGTTGCAAGGAAAATTGTTAGACATGTATTCAGGATAACCTGGGCTCGGGCGGTGGCGAGGGGAGTCCGCTC
TFDP1	NM_007111	6690973	THREE_PRIME	false	9	10	PLUS	TGCCGTCGTGATGAACACGCCTCCAACAGTTCCCTGAGCCATTTCTGTCACGTATGGCTCCAGAGCCTTGGGGACCAGACTTCTGGC
TFDP2	NM_001178138	6747805	CENTER	false	11	10	MINUS	CTCAAAGGTGTTGTCAAAATTGAAAAGATACTCAAACTTGTCACTGGAGATGCTGCAATCTATGACTGTT
TGFB1	NM_000660	6836773	THREE_PRIME	false	6	5	MINUS	GCGCCCGGGTTATGCTGGTTGTACAGGGCCAGGACCTTGCTGTACTGCGTGTCCAGGCTCCAAATGTA
TIMELESS	NM_003920	6708351	CENTER	false	13	12	MINUS	TCTAGGACCTTCTTCTTCTTCTTCCTTCTCTTCTTTTGTTTGTTCTGCACCACCAGGTTCCCACGGCTCCGACAGAATCGCTC
TP53	NM_001126114	6709182	THREE_PRIME	false	7	6	MINUS	CAAAGCTGTTCCGTCCCAGTAGATTACCACTGGAGTCTTCCAGTGTGATGATGGT
WEE1	NM_003390	6644367	FIVE_PRIME	false	1	2	PLUS	GCTCATAATCACTGGCTTCCATGTCTTCACCACAGGAATCATTCCAATACGTTCTCTTTCTACGACGACACTGTC